Los Angeles Compliance Requirements

Commercial buildings in LA face requirements from LADBS, LAFD, Cal/OSHA, SCAQMD, and LADWP.

Example building: A 32-story, 450,000 sq ft high-rise has 24 compliance requirements. You're previewing 9. Subscribe to track all of them.

Commercial Office

000 California Street, Los Angeles, CA

Los Angeles, CA

Sq Ft

450,000

Stories

32

Height

420 ft

High-Rise

Yes

Elevator

Yes

Boiler

Yes

Required Filings

24 periodic compliance requirements across 6 categories.

Fire & Life Safety

LA High-Rise Fire Safety Inspection

Los Angeles Fire Department - Industrial and Commercial Section

CFC / LAFC / Chief's Regulation No. 4

Required: Annual high-rise inspection by LAFD including fire pumps, standpipes, emergency systems, and life safety systems

Deadline

Annually; LAFD schedules inspection

Penalty

Violations, fines, potential closure order

โš  Why: LAFD Industrial and Commercial Section conducts annual inspections of ALL high-rise buildings in Los Angeles. High-rise is defined as buildings with occupied floors more than 75 feet above fire department access.

Evidence Required:

  • LAFD high-rise inspection report
  • Fire pump test certificate
  • Standpipe flow test (5-year)
  • Emergency system test records
Fire & Life Safety

LAFD Chief's Regulation 4 Fire Protection Testing

Los Angeles Fire Department, Bureau of Fire Prevention

LAFD Chief's Regulation No. 4

Required: Have fire protection systems tested annually by LAFD-certified tester; submit results via The Compliance Engine within 7 days

Deadline

Annual testing; results due within 7 days of test via The Compliance Engine (Brycer)

Penalty

Fines starting at $202/day; potential building closure

โš  Why: Chief's Regulation 4 requires commercial and multi-family buildings to have fire protection systems tested annually by LAFD-certified testers. This is SEPARATE from routine maintenance and must be submitted electronically. Failure to comply results in fines and potential building closure.

Evidence Required:

  • Regulation 4 test certificate
  • Compliance Engine submission confirmation
  • Deficiency repair records (within 30 days)
Fire & Life Safety

LA Fire Sprinkler System Inspection

Los Angeles Fire Department (LAFD)

CFC / NFPA 25

Required: Annual inspection and 5-year internal inspection of fire sprinkler systems per NFPA 25; maintain ITM records

Deadline

Annual visual inspection; 5-year internal pipe inspection

Penalty

Violations; potential insurance issues; liability exposure

โš  Why: NFPA 25 and California Fire Code require regular inspection, testing, and maintenance of fire sprinkler systems. LAFD verifies compliance during inspections.

Evidence Required:

  • Annual sprinkler inspection report
  • 5-year internal inspection report
  • ITM (Inspection, Testing, Maintenance) records